Jul. 20, 2020

Automatic weighing edible oil filling machine is the first equipment for the packaging of edible oil products, and it is also the key to maintaining the competitive development of the edible oil product market. Edible oil filling machines generally use flow meter filling. Flowmeter filling means that the computer automatically tracks the temperature and density of the oil and adjusts the oil delivery at any time so that the quality of the oil can reduce errors caused by changes in temperature and density. The accuracy is high. With the passage of time, the types of edible oil products have become more and more abundant, and the packaging forms of the products have also changed. But no matter what, the application of an edible oil filling machine is irreplaceable. Encouraged by science and technology, the technical performance of the vegetable oil filling machine has been greatly improved, especially in terms of filling accuracy, which has strict control and improvement. However, in addition, there are many common problems. Manufacturers need to pay more attention to control the occurrence of problems when operating the edible oil filling machine.

Vegetable Oil Filling Machine

Vegetable Oil Filling Machine

1. After the edible oil filling machine is closed for use, dripping occurs. After the edible oil filling machine has finished its production, there will be leakage afterward, and it should be operated from the following aspects:

1. Check whether the orifice of the filling nozzle is damaged or not, and you can remove the filling nozzle to repair the orifice. After repairing the aperture, gently smooth the surface of the orifice on the water sandpaper.

2. Check whether the ball valve in the filling head is damaged. If it is damaged, replace the ball valve.

Second, after the edible oil filling machine is turned on, the crank does not operate normally, what should I do?

The fixed rod of the edible oil filling machine is lowered, and the inner and outer pipes are firm when the syringe is pushed so that the crank cannot be rotated. The nut should be loosened, and the upper fixed rod is moved up to a proper position, and then the nut is tightened. If the inner and outer tubes are not clean and jammed when the syringe is assembled, the syringe needs to be removed for cleaning. Observe that the injection system is installed at the end of the bearing. To make it not work properly, it must be reinstalled.

Third, what kind of adjustment should be made if the edible oil filling machine has a faulty capacity error or a large capacity error?

There is air in the liquid pipe of the edible oil filling machine. Press the footswitch to exhaust. The liquid inlet pipe is not tightly sealed and leaks. Clamp the connecting pipe. The operation or filling speed is too fast, slow down appropriately. The liquid level of the material liquid tank is low, and the liquid level should be 1.52 meters. When filling large specifications, the feed tank is insufficient to make the liquid level unstable. You can increase the filling amount or re-close the ball valve above the filling head to reset the filling time.